[導(dǎo)讀] The document represents the con-sensus of the writing committee, which was developed asdescribed above. In writing a “consensus” document, it isrecognized that consensus does not mean that there wascomplete agreement among all writing gro

    《2011HRS美國(guó)植入除顫器、起搏器和心律失常檢測(cè)儀圍術(shù)期管理專家共識(shí)》內(nèi)容簡(jiǎn)介:

    The document represents the con-sensus of the writing committee, which was developed asdescribed above. In writing a “consensus” document, it isrecognized that consensus does not mean that there wascomplete agreement among all writing group members. Theexpert panel identified those aspects of perioperative man-agement of CIEDs for which a true “consensus” could beachieved. Surveys of the entire writing group were used toidentify these areas of consensus. For the purposes of thisdocument, they defined a consensus as 85% or greateragreement by the authors of this document.

    《2011HRS美國(guó)植入除顫器、起搏器和心律失常檢測(cè)儀圍術(shù)期管理專家共識(shí)》內(nèi)容預(yù)覽:

    Introduction
    The perioperative period for patients with pacemakers anddefibrillators poses unique challenges to ensure a high de-gree of patient safety. Rapid changes in CIED technology,expanding use of potential sources of electromagnetic in-terference (EMI) and confusing recommendations basedupon limited data have highlighted the need for a review ofthe known risks and a statement of recommendation. Forexample, in the past, there was great concern for phantomreprogramming, which is unintended random reprogram-ming due to EMI.1With current complex digital transmis-sion of programming signals, this is clearly no longer aconcern. Nonetheless, advice can be found in the literatureand in online websites that is contradictory and leaves thephysician without the ***rmation to make safe decisionsfor the physician's patients. Until recently, the website of atleast one CIED manufacturer suggested that every electro-surgical procedure required that all CIEDs needed to bereprogrammed to an inactive mode. This approach is out-side of standard of care and highlights the need for aconsistent statement.

    點(diǎn)擊下載***:《2011HRS美國(guó)植入除顫器、起搏器和心律失常檢測(cè)儀圍術(shù)期管理專家共識(shí)》


分享到:
  版權(quán)聲明:

  本站所注明來(lái)源為"愛(ài)愛(ài)醫(yī)"的文章,版權(quán)歸作者與本站共同所有,非經(jīng)授權(quán)不得轉(zhuǎn)載。

  本站所有轉(zhuǎn)載文章系出于傳遞更多信息之目的,且明確注明來(lái)源和作者,不希望被轉(zhuǎn)載的媒體或個(gè)人可與我們

  聯(lián)系z(mì)lzs@120.net,我們將立即進(jìn)行刪除處理

意見(jiàn)反饋 關(guān)于我們 隱私保護(hù) 版權(quán)聲明 友情鏈接 聯(lián)系我們

Copyright 2002-2025 Iiyi.Com All Rights Reserved

广丰县| 阜阳市| 广西| 修水县| 黑河市| 仁寿县| 炎陵县| 长顺县| 通海县| 通江县| 镇巴县| 牟定县| 永靖县| 隆昌县| 涪陵区| 盐源县| 谢通门县| 吐鲁番市| 大同县| 汾阳市| 卓资县| 新疆| 紫金县| 马尔康县| 禹州市| 南召县| 兰西县| 云和县| 洪洞县| 普兰县| 巫溪县| 公主岭市| 江阴市| 新闻| 华坪县| 信阳市| 伊宁县| 汶上县| 昌平区| 四会市| 潜山县|